Product Details:
Cooling Type | Oil Cooled |
Winding Material | Copper |
Number of Phase | Single Phase |
Brand | Macroplast |
Insulation Class | A |
Onsite Support Available | Yes |
Winding Turns | Step-Down Transformer |
Standards | IEC-60076, IEC 61869 |
Country of Origin | Made in India |
· Current Transformers are used to step down the current from a high value (say 200 A) to a lower value (1 or 5 A) suitable for measuring instruments like ammeter, energy meters and protective relays.
Product Details:
Brand | Macroplast |
Usage/Application | Metering and Protection |
Cooling Type | Oil Cooled |
Voltage Rating | Upto 132 KV |
Phase | Single Phase |
Nominal Current | Upto 3000 A |
Country of Origin | Made in India |
· Current Transformers are used to step down the current from a high value (say 200 A) to a lower value (1 or 5 A) suitable for measuring instruments like ammeter, energy meters and protective relays.
ADVANTAGES OF CURRENT TRANSFORMERS
· Provides electrical isolation between high voltage power circuit and measuring instruments
· Reduces insulation cost of measuring instruments
· Ensures the safety of operators
· Reduces utility losses
· Protects the device during fault conditions
TECHNICAL SPECIFICATIONS
System Voltage |
Upto 132 KV |
Primary Current |
Upto 3000 A |
Secondary Current |
1 A or 5 A |
Type |
Oil Immersed / Dry Type |
Rated Frequency |
50 Hz |
Accuracy Class (Metering) |
0.2s 0.2, 0.5s, 0.5, 1 |
Accuracy Class (Protection) |
3P, 5P, 10P |
Rated Burden |
2.5 VA to 50 VA |
Applicable Standard |
IS 16227, 2705 IEC 61869, 60044 |
FITTINGS & ACCESSORIES
· Porcelain Bushings
· Primary & Secondary Terminals
· Terminal Connectors
· Oil Level Indicator
· Nitrogen Filling Valve
· Pressure Release Device
· SS Bellows (optional)
· Junction Box (optional)
Product Details:
Brand | Macroplast |
Core Type | Wound CT |
Rated Voltage | Upto 132 KV |
Material | Copper |
Rated Power | Upto 50 VA |
Phase | Single Phase |
Country of Origin | Made in India |
System Voltage | Upto 132 KV |
Frequency | 50 Hz |
Price Range: Rs.14000 -80000
Product Details:
Brand | Macroplast |
Core Type | Wound CT |
Rated Voltage | Upto 132 KV |
Material | Copper |
Phase | Single Phase |
Country of Origin | Made in India |
Accuracy | 0.2s, 0.5s, 0.2, 0.5, 1 |
Rated Burden | Upto 50 VA |
Rated Secondary Current | 1 or 5 A |
Rated Primary Current | Upto 3000 A |
Product Details:
Brand | Macroplast |
Core Type | Wound CT |
Phase | Single Phase |
Rated Voltage | Upto 132 KV |
Material | Copper |
Rated Power | Upto 50 VA |
Country of Origin | Made in India |
Accuracy Class | 0.2s, 0.5s, 0.2, 0.5, 1 |
Tank Type | Dead Tank |
Product Details:
Secondary Voltage | 110 kV |
Accuracy Class | 0.2, 0.5 |
Core Structure | Toroidal |
Frequency | 50 / 60 Hz |
Rated Voltage | 220 kV |
Rated Burden | 10 - 500 VA |
Product Details:
Accuracy Class | 1.0, 0.2, 0.5 |
Rated Burden | 10 - 500 VA |
Core Structure | Toroidal |
Frequency | 50 Hz |
Nominal Rated Voltage | 66 kV |
Product Details:
Core Type | Wound Type |
Rated Burden | 2.5 - 30 VA |
Frequency | 50 Hz |
Core Structure | Toroidal |
Nominal System Voltage | 33 kV |
Product Details:
Brand | Macroplast |
Phase | Single Phase |
Winding Material | Copper |
Current Range | Upto 3000 A |
Frequency | 50 Hz |
Applications | Metering and Protection |
Country of Origin | Made in India |
· Current Transformers are used to step down the current from a high value (say 200 A) to a lower value (1 or 5 A) suitable for measuring instruments like ammeter, energy meters and protective relays.
Additional Information:
Product Details:
Brand | Macroplast |
Phase | Single Phase |
Winding Material | Copper |
Current Range | Upto 3000 A |
Applications | Metering and Protection |
Country of Origin | Made in India |
· Current Transformers are used to step down the current from a high value (say 200 A) to a lower value (1 or 5 A) suitable for measuring instruments like ammeter, energy meters and protective relays.
ADVANTAGES OF CURRENT TRANSFORMERS
· Provides electrical isolation between high voltage power circuit and measuring instruments
· Reduces insulation cost of measuring instruments
· Ensures the safety of operators
· Reduces utility losses
· Protects the device during fault conditions
TECHNICAL SPECIFICATIONS
System Voltage |
Upto 132 KV |
Primary Current |
Upto 3000 A |
Secondary Current |
1 A or 5 A |
Type |
Oil Immersed / Dry Type |
Rated Frequency |
50 Hz |
Accuracy Class (Metering) |
0.2s 0.2, 0.5s, 0.5, 1 |
Accuracy Class (Protection) |
3P, 5P, 10P |
Rated Burden |
2.5 VA to 50 VA |
Applicable Standard |
IS 16227, 2705 IEC 61869, 60044 |
FITTINGS & ACCESSORIES
· Porcelain Bushings
· Primary & Secondary Terminals
· Terminal Connectors
· Oil Level Indicator
· Nitrogen Filling Valve
· Pressure Release Device
· SS Bellows (optional)
· Junction Box (optional)
Additional Information:
Product Details:
Phase | Three Phase |
Frequency | 50 Hz |
Rated Burden | 2.5 - 30 VA |
Nominal System Voltage | 11 kV |
Core Structure | Toroidal |
Product Details:
Rated Burden (VA) | 2.5 - 30 VA |
Core Type | Wound |
Frequency | 50 Hz |
Core Structure | Toroidal |
Rated Secondary Current | 5A |
Product Details:
Cooling Type | Dry Type |
Frequency | 50 Hz |
Rated Voltage | 0.66 kV |
Accuracy Class | 1 or 3, 0.2, 0.5 |
Material | Copper |
I Deal In | New Only |
Country of Origin | Made in India |
Core Type | Ring Core and Wound CT |
Primary current | Upto 3000 A |
Phase | 1 or 3 phase |
Coil Structure | Toroidal |